Skip to main content
Fire-Rated High-Speed Door
Turbo & Spiral Rigid Doors

Fire-Rated High-Speed Door

Anbixin fire-rated rapid doors are designed for emergency egress and fire safety, featuring rapid closing, fire resistance, forced opening, and audible-visual alarms. They are a critical device for ensuring personnel safety and maintaining clear fire routes.

Fire-Rated High-Speed Door is a rigid high-speed door configuration. A rigid high-speed door is a powered industrial door built from rigid insulated slats that opens and closes at high speed, combining wind resistance, security and temperature separation at high-traffic openings.

Anbixin Fire-Rated Rapid Doors - Guardians of Life Safety Routes

Fire-Rated Rapid Door

In emergency situations like fires, the unobstructed state of fire exits directly impacts the safety of personnel evacuation. Anbixin fire-rated rapid doors, as a professional hard-wall rapid door product, are designed for fire emergency routes. They can respond quickly, closing completely in a very short time to form a reliable fire and smoke barrier, and are an indispensable part of modern building fire safety systems.

Core Advantages and Key Technologies

Fire-Rated Rapid Door

  • Super-fast response speed: The door can fully close in 3 seconds, effectively blocking the spread of fire and smoke to buy valuable time for evacuation.
  • High-strength fire resistance: The door leaf is made of special fire-resistant materials, which can withstand at least 90 minutes of flame exposure in standard fire tests, effectively isolating the fire and protecting the safety of the building interior.
  • Forced opening function: An internal emergency release device allows manual or electric forced opening of the door when the fire alarm system is triggered, ensuring firefighters can enter quickly for firefighting and rescue.
  • Audible-visual alarm system: The integrated sound and light alarm on the door emits a strong audible and visual signal when the door is activated or closed, alerting surrounding personnel and enhancing the warning effect of the system.

Detailed Technical Specifications

Fire-Rated Rapid Door

  • Door leaf thickness: 40 mm polyurethane foam with an embedded steel frame, providing high strength and good thermal insulation performance.
  • Closing speed: The standard closing speed is 3 seconds per meter, which can be adjusted according to needs, with the fastest speed reaching 2 seconds per meter.
  • Fire resistance rating: Meets the fire resistance time requirements for fire doors in GB 50016, 'Code for Fire Provisions in Building Design', typically 90 minutes.
  • Door size: Width ranges from 1.2 meters to 12 meters, with a height up to 4 meters, customizable according to actual passage dimensions.
  • Driving method: Uses high-precision synchronous toothed belt or synchronous chain drive, running smoothly and quietly, ensuring the door remains stable during high-speed operation.
  • Sealing performance: The bottom of the door uses a high-strength rubber seal, combined with side seals, to effectively prevent the penetration of smoke and hot air, maintaining the air environment inside the passage.

Technical specifications

ParameterTypical value
Door leaf thickness40 mm Polyurethane Foam
Closing speed3 seconds/meter (adjustable to 2 seconds/meter)
Fire resistance rating90 minutes (compliant with GB 50016)
Door sizeWidth 1.2m - 12m, Height 4m
Driving methodSynchronous toothed belt/chain drive
Sealing performanceRubber seals, prevents smoke and hot air penetration

Values are typical configuration ranges. Final selection depends on opening size, cycle duty and site conditions.

Installation and selection notes

This model belongs to the rigid high-speed doors family, where rigid slat construction is chosen where wind load, forced-entry resistance and thermal separation must coexist with frequent traffic. Confirm safety-edge and photocell coverage for the actual traffic pattern. Confirm the clear opening width and available headroom before choosing the track arrangement.

Frequently asked questions

What is Fire-Rated High-Speed Door?

Fire-Rated High-Speed Door is a rigid high-speed door configuration. A rigid high-speed door is a powered industrial door built from rigid insulated slats that opens and closes at high speed, combining wind resistance, security and temperature separation at high-traffic openings.

Which application scenarios are covered?

The configurations discussed on this page cover super-fast response speed, high-strength fire resistance, forced opening function. Each scenario has different requirements for opening speed, sealing and cycle frequency.

Which parameters should be verified before selection?

Before ordering, verify door leaf thickness, closing speed, fire resistance rating against the actual site conditions. Values on this page are typical ranges, not a substitute for a door schedule.

How does rigid high-speed door fit industrial facilities?

For industrial facilities, rigid slat construction is chosen where wind load, forced-entry resistance and thermal separation must coexist with frequent traffic. Confirm the final arrangement with the project door schedule and the site's safety requirements.

Standards and parameters to verify

When specifying rigid high-speed doors for industrial facilities, check the following against the project door schedule. The standards listed are the references normally used when reviewing an industrial door specification; they are not a certification claim for any specific installation.

ReferenceWhat to verify
EN 13241Product standard for industrial, commercial and garage doors and gates
EN 12424Wind resistance classification for the exposed elevation
EN 12425Resistance to water penetration
EN 12426Air permeability of the closed door
EN 12428Thermal transmittance where temperature separation is required
EN 12453Safety in use of power-operated doors
EN 12604Mechanical aspects of doors and gates
Typical operating speed0.5-1.2 m/s across models in this product family; confirm the required cycle time before selection.

Confirm the safety devices cover the actual pedestrian and forklift traffic pattern. Final values depend on opening size, cycle duty and site conditions.

Pain Points Solved

In emergency situations such as fires, traditional doors cannot close quickly, leading to the spread of fire and smoke, threatening personnel safety.

Gallery

Need a Reliable Solution for Your Project?

Tell us about your application and requirements — our team will help you specify the right product.

Request a Quote